Setting FLUIDWELL Pump Rate Display
FLUIDWELL F012-P (Rate/ Totalizer)
On the pump rate display, set the following parameters as listed per the manufacturers instructions, usually using for Single Pump on Oilfield Services;Figure 1.1 - Fluidwell F012-P |
For TOTAL:
- Set UNIT
parameter to bbl
- Set
DECIMALS parameter to 111111.1
- Set K-FACT to
5554.430 for plunger size 4.5in FE*
- Set K-FACT dECS
to 0
*This is
calculated by the formula:
(#MPU TEETH X DRIVELINE RPM) / BPM, with values
taken from the pump schedule.
For FLOWRATE:
- Set UNIT
parameter to bbl
- Set TIME
parameter to MIN
- Set
DECIMALS parameter to 111111.1
- Set K-FACT
to 5554.430 for 4.5in FE*
- Set K-FACT dECS
to 0
- Set
CALCULATE parameter to 1
- Set CUT-OFF
to 0.1
For DISPLAY:
- Set
FUNCTION to TOTAL
- Set
BACKLIGHT to OFF (or GREEN/ AMBER)
For POWERMAN:
- Set LCD NEW
to FAST
- Set
BATTMODE to OPERATE
For
FLOWMETER:
- Set SIGNAL
to NPN LP
- For Details, download User Manual here.