SPN 3512 - FMI 3 (Fault Code 2185)
SPN3512 FMI3
Sensor Supply 4 Circuit - Voltage Above Normal or Shorted to High Source
ISB, ISC, and ISL with CM2150 - Accelerator Pedal or Lever Position Sensor Supply |
Fault Code: 2185
PID(P), SID(S): S232
SPN: 3512
FMI: 3/3
Lamp: Amber
REASON: Sensor Supply 4 Circuit - Voltage Above Normal or Shorted to High Source. High voltage detected at +5 volt sensor supply circuit to the accelerator pedal position sensor.
EFFECT: Engine will only idle.
Circuit Description:
Sensor supply 4 of the electronic control module (ECM) provides a 5 volt supply to the accelerator pedal position sensor. The accelerator position sensor is a hall effect sensor attached to the accelerator pedal. The accelerator position sensor varies the signal voltage to the ECM as the accelerator pedal is depressed and released. Low signal voltage is received by the ECM when the accelerator pedal is at 0 percent. A high signal voltage is received by the ECM when the accelerator pedal is at 100 percent. The accelerator pedal position circuit contains an accelerator pedal position 5 volt supply, accelerator pedal position return, and accelerator pedal position signal.
Component Location:
The accelerator pedal assembly is located in the cab.
Conditions for Running the Diagnostics:
This diagnostic runs continuously when the keyswitch is in the ON position.
Conditions for Setting the Fault Codes:
The ECM detects that the sensor supply 4 signal voltage is more than 5.25-VDC for more than 1 second.
Action Taken When the Fault Code is Active:
• The ECM illuminates the amber CHECK ENGINE light immediately when the diagnostic runs and fails.
• The engine will only idle.
Conditions for Clearing the Fault Code:
The ECM will turn off the amber CHECK ENGINE light immediately after the diagnostic runs and passes.
Shop Talk:
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM.
This fault code can be caused by a short circuit to a voltage source in the OEM harness or a short circuit to an actuator signal circuit that is greater than 5-VDC.