Caterpillar ET Software: Copy Configuration Function
CAT ET - Copy Configuration
Figure 1.1 - Copy Configuration |
The Copy Configuration function allows configuration parameter data to be
sent to and from ECMs. Current functions available under Copy Configuration are:
(1). Fleet Configuration
The Fleet Configuration function allows configurable information that is common to several ECMs to be copied. NOTE: This function may be accessed without an ECM connection by selecting Open from the File menu, and then selecting Fleet Configuration File. The Fleet Configuration screen will be displayed.
Figure 1.2 - Fleet Configuration File (Open) |
Figure 1.3 - Fleet Configuration File |
Figure 1.4 - Fleet Configuration |
Save Fleet Configuration Data to a File
To save the configuration data from the ECM:1). Connect CAT ET Software to the ECM. Read More: How to Connecting Caterpillar ET Software to the ECM.
2). Select Service - Copy Configuration - Fleet Configuration as Figure 1.1 above. If no recently loaded data is available, the No data is available… message box is displayed. Click Yes to load the data from the ECM.
Figure 1.6 - Fleet Configuration data was loaded |
3). Or click on Load from ECM, then Save to File.
4). By default, the file name is saved by ECM Serial Number, date, and time.
#Download here for example: FC7P00167_190107065746.xml
FC7P00167 - ECM Serial Number
190107 - Date download was taken (January 07, 2019)
065746 - Time download was taken to the second (06:57:46 AM)
Loading Data from a File (when connected)
→Click on Load from File to load data from a file to the ECM to be programmed.
→Select a file and click Open to load the data. A message box that includes the
name of the ECM from which data was loaded, the time, and the date the data was
retrieved is displayed.
→Click OK on "The current Fleet
Configuration data came from" message box. The Fleet Configuration screen will
be displayed.
#Programming the ECM
To program the ECM:
(2). ECM Replacement
The ECM Replacement function allows configurable information to be copied to an ECM. This function may be accessed without an ECM connection by selecting Open from the File menu, and then selecting ECM Replacement File. The ECM Replacement screen will be displayed, or through Service - Copy Configuration - ECM Replacement.
Loading Data from the ECM
To load data from the ECM:
4). When the data has been successfully loaded, The data has been successfully
loaded… message box is displayed. Click OK. The ECM Replacement screen is
displayed with the Program ECM button enabled.
Loading Data from a File (when connected)
Note: The data must be loaded before an ECM can be
programmed.
→Click on Program ECM.
→The Testing ECM… progress bar displays the completion status of the progress
of the test. Once the test is complete, the Programming ECM progress bar
displays the progress of the programming.
Figure 1.7 - Testing ECM... |
→When the data has been successfully uploaded, the Programming Complete message
box displays. Click OK.
Figure 1.8 - Programming Complete |
(2). ECM Replacement
The ECM Replacement function allows configurable information to be copied to an ECM. This function may be accessed without an ECM connection by selecting Open from the File menu, and then selecting ECM Replacement File. The ECM Replacement screen will be displayed, or through Service - Copy Configuration - ECM Replacement.
Figure 1.9 - ECM Replacement |
Figure 2.1 - ECM Replacement - Load from File |
Figure 2.2 - ECM Replacement data was loaded |
Loading Data from the ECM
To load data from the ECM:
1). Select Copy Configuration from the Service menu, and then select ECM Replacement from the sub-menu.
If no recently loaded data is available, the No data is available… message
box is displayed. Click Yes to load the data from the ECM.
Figure 2.3 - No data is available |
Figure 2.4 - ECM Replacement data was loaded |
2). Or click on Load from ECM, then Save to File.
3). By default, the file name is saved by ECM Serial Number, date, and time.
Figure 2.5 - Save to File ECM Replacement File |
Figure 2.6 - ECM Replacement data saved |
Loading Data from a File (when connected)
→Click on Load from File to load data from a file to the ECM to be programmed.
→Select a file and click Open to load the data. A message box that includes the name of the ECM from which data was loaded, the time, and the date the data was retrieved is displayed.
→Click OK on The current Fleet Configuration data came from message box. The Fleet Configuration screen will be displayed.
#Programming the ECM
#Programming the ECM
To program the ECM:
Note: The data must be loaded before an ECM can be programmed.
→Click on Program ECM.
→The Testing ECM… progress bar displays the completion status of the progress of the test. Once the test is complete, the Programming ECM progress bar displays the progress of the programming.
Figure 2.7 - Testing ECM... |
→When the data has been successfully uploaded, the Programming Complete message box displays. Click OK.
Figure 2.8 - Programming Complete |
(3). Product ECM Replacement
To save the Product ECM Replacement from the ECM:
1). Select Copy Configuration - Product ECM Replacement.
Figure 2.9 - Product ECM Replacement |
2). Create File (Save As) for Product ECM Replacement.
Figure 3.1 - Create File Product ECM Replacement |
3). Click Open ECM Replacement... to open data as saved before.
Read More:
Change Units of Measure on CAT Messenger Display
Change Measurement System on Caterpillar ET Software
Change Units of Measure on CAT Messenger Display
Change Measurement System on Caterpillar ET Software
Blog.Teknisi
nice !! You are such a good person and I like your blog. Please continue. - New Holland 3600
ReplyDeleteIf you are looking for a pickup for transporting goods. Then, try this
ReplyDeleteAshok Leyland Bada Dost
Please keep us up to date like this. Thank you for sharing. 스포츠토토
ReplyDelete