Detroit Diesel Diagnostic Link (DDDL) Software: Normal Instrumentation

Normal Instrumentation (DDDL v6.46)

Figure 1.1 - Normal Instrumentation (Turbo ^7)
The instruments in the Instrumentation window can be grouped together on tabs in two possible ways. To group the instruments so that those for the same type of measurement (such as mechanical, temperature or pressure) are on the same tab:

#To run Normal Diagnostic:
1). Connect DETROIT Engine (60 Series) using Detroit Diesel Diagnostic Link (DDDL v6.46). Read More: How to Connecting the DETROIT Engine using Detroit Diesel Diagnostic Link (DDDL).

2). Choose Normal Instrumentation from the Diagnostics menu. The toolbar button displays the diagnostic or normal pages of the Instrumentation window depending on which was last displayed.
Figure 1.2 - Normal Instrumentation (Diagnostics)

3). A radio button will appear beside the command in the menu when it is selected. The window displays live data measurements from the ECM connected to your PC.
Figure 1.3 - Normal Instrumentation (Mech ^1)
Figure 1.4 - Normal Instrumentation (Press ^2)
Figure 1.5 - Normal Instrumentation (Temp ^3)
Figure 1.6 - Normal Instrumentation (Ind-1 ^4)
Figure 1.7 - Normal Instrumentation (Ind-2 ^5)
Figure 1.8 - Normal Instrumentation (ESS ^6)

4). You can customize the information shown in the instrumentation window using the Graph and User menus.
(A). Clicking on the User tab in the Instrumentation window displays the User page:
→The User page allows you to monitor your own selection of measurements by assigning them to appropriate instruments.
→The page provides four meters, one digital meter and three indicators.
→To choose which measurements to monitor:
Figure 1.9 - Normal Instrumentation (User ^9)
Press Modify to display the Modify user page dialog box:
→For each instrument, choose what measurement you want it to display from the drop-down list box below the instrument.
→When you close the Modify user page dialog box, the current values of the chosen measurements will be shown on the instruments.

#To save the current user page settings in a file:
→Press Save to display standard Windows Save As dialog box:
→Select the folder in which to save the file.
→Enter a File name for the file.
→Press Save to save the file and close the dialog box:
#To load a set of previously saved graph page settings:
→Press Load to display a standard Windows Open dialog box.
→Use the dialog box to locate the folder holding the required file.
→Click on the File name to select it.
→Press Open to close the dialog box and load the settings.

(B). Clicking on the Graph tab in the Instrumentation window displays the Graph page:
→The Graph page allows you to display traces showing the variation of selected measurements over time. Read More: Graph Page on Detroit Diesel Diagnostic Link (DDDL) Software.
Figure 2.1 - Normal Instrumentation (Graph ^8)