FREE ALLISON DOC Software: Calibration Information on ALLISON Transmission
Calibration Information
Figure 1.1 - 5th Gen Calibration Information (4700 OFS) |
Calibration Information
Current TCM calibration information (i.e calibration setting) can be displayed using the Calibration Information button.
#Pre-5th Gen Calibration Information
1). Connect ALLISON Transmission using Allison DOC Software. Read More: How to Connecting ALLISON Transmission using ALLISON DOC Software.
2). Select Calibration Information button.
3). The Calibration Information window for the Transmission type displays.
Figure 1.2 - 4th Gen Calibration Information (4700 OFS) |
The TCM Calibration Information displays data in 5 sections:
- Customer Modifiable Constant (CMC) - displays current values/states/thresholds of those parameters to which the Transmission would react, and that the user (with the proper authorization) could change or modify.
- Torque Converter Temperature - displays information related to Torque Converter Temperature model information (only displayed for 1000/2000 Product Families with Allison 4th Generation Control systems, MY10 and later).
- Calibration - displays static data describing both software and hardware installation.
- SEM/LRTP and Autodetect Information - displays information related to Shift Energy Management (SEM), Low Range Torque Protection (LRTP), and Autodetect information.
- Input/Output Functions and Signal Information - displays I/O functions and signal states (refer to Data Monitor section).
#5th Gen Calibration Information
1). Select Calibration Information button.
2). The Calibration Information window for the Transmission type displays (as Figure 1.1 above).
The TCM Calibration Information displays data in 5 sections:
- Customer Modifiable Constant (CMC) - displays current values/states/thresholds of those parameters to which the Transmission would react, and that the user (with the proper authorization) could change or modify.
- Torque Converter Temperature - displays information related to Torque Converter Temperature model information (only displayed for 1000/2000 Product Families with Allison 5th Generation Control systems, MY10 and later).
- Calibration - displays static data describing both software and hardware installation.
- Input/Output - displays I/Os that can be changed in reprogramming.
- Input/Output Functions and Signal Information - displays I/O functions and signal states (refer to Data Monitor section).
5th Gen Additional Calibration Information
→Press the Additional Calibration Information button.
Figure 1.3 - 5th Gen Additional Calibration Information (4700 OFS) |
The Additional Calibration Information displays data in 2 sections:
- Read Only Calibration Information/Constants - displays current values/states/thresholds of those parameters to which the Transmission would react, and that the user cannot modify.
- SEM/LRTP and Engine Torque Information - displays information related to Shift Energy Management (SEM), Low Range Torque Protection (LRTP), and Engine Torque Information.
Read More:
Blog.Teknisi
0 Response to "FREE ALLISON DOC Software: Calibration Information on ALLISON Transmission"
Post a Comment