#Purpose:
The Special Tests function allows a specific diagnostic test to be selected
so that it may be triggered. The tests that appear in the list depend on the
current ECM. Today, we'll check the Shut Off Solenoid Test.
#Accessing:
To run the Special Tests function:
1). Open CAT ET and connect to the ECM. Read More: How to Connecting Caterpillar ET Software to the ECM.
2). Select Diagnostic Tests from the
Diagnostics menu.
Figure 1.2 - Diagnostic Tests (Diagnostics) |
3). Select Special Tests from the submenu. The Special
Tests screen is displayed, then click Start button.
Figure 1.3 - Special Tests |
4). Select Shut Off Solenoid Test, and click Start button to begin testing.
Figure 1.4 - Shut Off Solenoid Test (Not Active) |
5). Click Yes to continue the test.
Figure 1.5 - Click "Yes" |
6). Shut Off Solenoid Test State will change from Not Active to Active.
Figure 1.6 - Shut Off Solenoid Test (Active) |
7). Please measure output voltage (12/ 24 VDC) at Shut Off Solenoid connector.
Figure 1.7 - Start (Active) |
Figure 1.8 - Stop (Not Active) |
#Screen Layout
The Special Tests screen has the following areas:
a). Display Area
The Special Tests display area has two columns:
- Description – Provides the name of the parameter
- State – Displays the current state of the parameter: "Not Installed", "Active", or "Not Active".
The Special Tests display area contains all of the available Special Tests
for the currently selected ECM. Each ECM has one or more Special Tests
displayed. However, only one test may be selected at a time.
b). Button
The buttons available in the Special Tests screen are:
- Start – After selecting one of the parameters, click this button to begin testing. This button is disabled until after the Stop button is clicked.
- Stop – Click this button to stop the selected special test in progress. This will change the state of the test. The Stop button is disabled until the Start button has been clicked.
- Stop All – Click this button to stop all special tests in progress. This button is enabled only when one or more tests are activated.