FREE Caterpillar ET Software: PTO Configuration Test - Remote Switches
Remote Switches
Figure 1.1 - Remote Switches (Increase/ Decrease) |
1). Use CAT ET to Check the Programming of the Parameter Dedicated PTO Parameters.
→Connect CAT ET to the data link connector. Read More: How to Connecting Caterpillar ET Software to the ECM.
→Access the Dedicated PTO Parameters on CAT ET. Note the programming of the parameter PTO Configuration (Remote Switches). Read More: PTO Configurations for On-Highway Trucks (Caterpillar Engines).
Figure 1.2 - PTO Configuration (Remote Switches) |
2). Check the Circuit for the PTO On/Off Switch.
→Activate the PTO operation.
→Access the CAT ET Status screens that display the following status parameters. Read More: Status Tool on Caterpillar ET Software.
- PTO Config (Remote Switches)
- PTO On/Off Switch - J1/P1:56
→Verify that each of the interlocks for the PTO are set. Then, while the CAT ET Status screen is being monitored, move the PTO On/Off Switch to the ON and OFF position.
Figure 1.3 - PTO On/Off Switch (ON) |
3). Check the Status of the Set/ Resume Input.
→View the Status parameter on CAT ET for the Remote PTO Set Switch - J1/P1:58 and for the Remote PTO Resume Switch - J1/P1:60.
→While the Status screen of CAT ET for the switch is being monitored, perform the following procedure in order:
-Put the Remote PTO Set/Resume Switch in the Set position. The status of the Remote PTO Set Switch - J1/P1:58 changes from "OFF" to set switch "ON" when the Remote PTO Set Switch is moved to the SET position, and the Engine RPM will increase.
Figure 1.4 - Remote PTO Set Switch (ON) |
Figure 1.5 - Remote PTO Resume Switch (ON) |
-Also monitor the Status of the PTO Set RPM, will changes from 0 RPM to actual Engine Speed (will equal) and the PTO Kickout (Not Kicked Out).
Figure 1.6 - PTO Set RPM |
-PTO Kickout value will changes to PTO Switch Turned Off when the PTO On/Off Switch is turned to the "OFF" position.
Figure 1.7 - PTO Kickout (PTO Switch Turned Off) |
4). Monitor using the Real Time Graphing while simulate the PTO Configuration Test (Remote Switches). Read More: Real Time Graphing using Caterpillar ET Software.
Figure 1.8 - PTO Config (Remote Switches) |
When the PTO Configuration is programmed to Remote Switches or to Remote Throttle and the PTO On/Off Switch is On, the following circuits are ignored:
• Service Brake Pedal Position Switch 1
• Service Brake Pedal Position Switch 2
• Clutch Pedal Position Switch
• Neutral Switch
• Accelerator Pedal Position Sensor
• Cruise Control Set/Resume Switch that is located in the Cab.
Read More:
Blog.Teknisi
0 Response to "FREE Caterpillar ET Software: PTO Configuration Test - Remote Switches"
Post a Comment