FREE Cummins INSITE Software: ECM Time on CUMMINS Engines
ECM Time - Engine Hours
Figure 1.1 - Total ECM Time (Key On Time) |
During operation of the Engine, the ECM records and stores information related to a wide range of events, which includes time stamping. Two different measures of time are available:
1). ECM Time (Key On Time), Total ECM run time as recorded by the ECM/ Total ECM run time, to date (HH-MM-SS), refer to Figure 1.1 above, while Engine Hours (Engine Run Time), Total Engine run time for all ECMs on this Engine. Prior ECM times must be entered by the user (HH-MM-SS).
Figure 1.2 - Total Engine Hours (Engine Run Time) |
2). ECM Real Time, which gives a date and 24 hours based time stamp. This feature
allows automatic synchronization of ECM Real Time to match the PC Date and Time
or a manual change to enter the current ECM Real Time. It is also important to
ensure that the local time zone is set correctly to maintain the correct local
time.
A battery backup is used to maintain constant
power to the Real Time Clock. If the battery backup is not present, a power loss
to the Real Time Clock (such as disconnecting the batteries in excess of 5
seconds) causes a loss of Real Time Clock accuracy. This situation generates
fault code 319, and the maintenance lamp will light.
#Enabling the Real Time Clock
To enable the Real Time Clock:
a). From Advanced ECM Data, select Real Time Clock. Read More: Advanced ECM Data on Cummins INSITE Software (CUMMINS Engines).
Figure 1.3 - Real Time Clock |
Figure 1.4 - Enable Real Time Clock |
→Automatically setting the Real Time Clock
-Verify that the Local PC Date and Time are correctly displayed.
If this needs to be corrected, it must be done within Windows. Select Undo
and close INSITE™. Adjust the PC Date and Time as needed. If the Local PC Time and Date are correct, select the Auto
Set button.
→Manually setting the Real Time Clock
-Verify that the Local Time Zone is correct, and then set the
correct date and time in the ECM Date and Time frame. Select Apply to save these settings to the ECM.
d). Follow the prompts to save the changes to the ECM.
Figure 1.5 - Select OK to continue |
e). Select Undo to exit the Real Time Clock window without sending changes to the ECM.
If the ECM is replaced, total Trip Information is lost and Engine Time Offset, Engine Distance Offset, ECM Time Offset, and ECM Distance Offset must be
entered. This enables accurate tracking of total Trip Information for the life
of the Engine with the new Electronic Control Module/ ECM.