Start Data Recording using the Dialog System DiaSys (MTU Engine/ ECU-7 Diesel)
DiaSys v2.74
Figure 1.1 - Offline y(t) curve |
#Start Data Recording
Starts data recording and opens a list of measured data and a Y(t) graphic.
1). Establish datalink to controller (Online). Read More: Program Startup with the Dialog System DiaSys (MTU Engine/ ECU-7 Diesel).
Figure 1.2 - Available functions (ECU-7) |
2). Select Start data recording...
→Select sensor for data recording.
→Display of measured data, select OK.
Figure 1.4 - Measured data |
Figure 1.5 - List of measure data (Sensors) |
→Select OK.
Figure 1.6 - Online y(t) curve |
3). Stop Recording
→Select Stop recording to stops the data recording.
→By pressing the Yes button, it is possible to save the recorded data using a
specified file name.
→Select Evaluate recorded data...
→Open previously saved data for offline analysis in a y(t)-curve.
→Select Open.
Figure 1.7 - Data recording |
→Select sensors for y(t) curve. Select OK.
This dialog is used to select sensors for display in a y(t)-curve.
Figure 1.8 - Display of measured data |
Figure 1.9 - Offline y(t) curve |
#Label
→Measured data - Select preferred recording
→Available sensors - Available sensors of the selected recording
→Saved graphics or lists - The saved group can be selected here
→Selected for display - List of selected sensors
(>>) - Select all available sensors
(>) - Selects the chosen 'Available sensors'. Single sensors can be selected using
double-click. To mark several sensors, drag the mouse over the preferred
sensors or press the Shift key to select more than one sensor.
(<) - Selects the chosen 'Selected for display'. Single sensors can be deselected
using double-click. To mark several sensors, drag the mouse over the preferred
sensors or press the Shift key to select more than one sensor.
(<<) - Deselect all sensors.
Read More:
Blog.Teknisi
0 Response to "Start Data Recording using the Dialog System DiaSys (MTU Engine/ ECU-7 Diesel)"
Post a Comment