Translate

Connecting to/ Disconnecting from the Electronic Service Tool (EST - Perkins Engine)

Electronic Service Tool (EST)

Figure 1.1 - ECM Perkins 1104D

#PURPOSE
A. Connect
The Connect function initiates data link connection. This function is available when no data link is currently active.

When this function is selected, the service tool continues with the same data link connection procedures used during initial startup of the application. When a data link is established, the service tool returns to the main menu and displays the ECM Summary screen. When a data link connection is not established, the service tool provides information for correcting the problem.

B. Disconnect
The Disconnect function allows the current data link connection between the service tool and the ECM to be removed. This function is available when a data link connection is currently active. All service tool functionality, menus, and toolbars are updated according to the state of the connection.


#INSTRUCTION
A). To Start a Connection...
→Click the Connect icon on the toolbar (if default is set), select Connect from the File menu, or push the F8 key. The Connection message box is displayed while the service tool attempts to establish communications with the data link.
Figure 1.2 - Connect (F8)
→When communications are successfully established and a single ECM is found, the ECM Summary screen displays.
Figure 1.3 - 1 ECM detected
Figure 1.4 - ECM Summary
→If first connecting to the ECM, it will automatically create/ download the Product Status Report from the ECM.
Figure 1.5 - Product Status Report
→When communications are successfully established and multiple ECMs are found, the ECM Selector dialog box displays. If the service tool connects to an ECM that is not supported by the subscription, the service tool displays a message and immediately disconnects.
→To cancel all attempts to communicate with the ECM, click the Stop Connect button on the Connection message box. All functions that require an active data link connection are disabled. The service tool displays a blank main screen. The status bar is updated with the message Disconnected.


B). To Stop a Connection...
Click the Disconnect icon on the toolbar, select Disconnect from the File menu, or push the F8 key. The blank service tool main screen will be displayed.
Figure 1.6 - Blank (Main Screen)


#PREFERENCES
→This screen allows the communication (COM) port and Baud Rate settings to be set for the communication adapter. These settings can also be set from the Communications tab in the Preferences dialog box of the service tool.
Figure 1.7 - Preferences (Modify)
→To view the Preferences screen, select Preferences from the Utilities menu.
Figure 1.8 - Preferences










Blog.Teknisi

Subscribe to receive free email updates:

0 Response to "Connecting to/ Disconnecting from the Electronic Service Tool (EST - Perkins Engine)"

Post a Comment